| |
Cylinder Volume – cu ft (L) |
|
|
|
|
|
|
15.8 |
(447.4) |
| Speed |
Tumbler Speed – RPM |
|
|
|
|
|
|
45 |
— |
| |
Motor Size – 60 Hz Model – hp (kW) |
|
|
|
|
|
|
1 |
(0.75) |
| |
Motor Size – 50 Hz Model – hp (kW) |
|
|
|
|
|
|
0.75 |
(0.56) |
| Airflow |
60 Hz Model – cfm (M3/min) |
|
|
|
|
|
|
910 |
(25.8) |
| |
50 Hz Model – cfm (M3/min) |
|
|
|
|
|
|
760 |
(21.5) |
| Dimensions |
Cabinet Height – in (cm) |
|
|
|
|
|
|
72 1/4 |
(183.5) |
| |
|
|
|
|
|
|
|
|
|
| |
Cabinet Width – in (cm) |
|
|
|
|
|
|
34 1/2 |
(87.6) |
| |
Cabinet Depth – in (cm) |
|
|
|
|
|
|
48 |
(121.9) |
| |
Door Opening – in (cm) |
|
|
|
|
|
|
25 5/8 |
(65.1) |
| |
Floor to Door Bottom – in (cm) |
|
|
|
|
|
|
27 1/4 |
(69.2) |
| |
Cylinder Diameter – in (cm) |
|
|
|
|
|
|
32 1/2 |
(82.6) |
| |
Cylinder Depth – in (cm) |
|
|
|
|
|
|
33 |
(83.8) |
| |
Lint Screen Area – sq in (sq cm) |
|
|
|
|
|
|
708 |
(4568) |
| |
|
|
|
|
|
|
|
|
|
| Weight |
Net Weight – lbs (kg) |
|
|
|
|
|
|
540 |
(244.9) |
| |
|
|
|
|
|
|
|
|
|
| Shipping |
Shipping Weight – lbs (kg) |
|
|
|
|
|
|
590 |
(267.6) |
| |
|
|
|
|
|
|
|
|
|
| |
Shipping Height – in (cm) |
|
|
|
|
|
|
77 1/4 |
(196.2) |
| |
Shipping Width – in (cm) |
|
|
|
|
|
|
36 |
(91.4) |
| |
Shipping Depth – in (cm) |
|
|
|
|
|
|
51 1/2 |
(130.8) |
| |
|
|
|
|
|
|
|
|
|
| Gas (Gas Models Only) |
Gas Supply Connection – in (mm) |
|
|
|
|
|
|
1/2 |
(12.7) |
| |
|
|
|
|
|
|
|
|
|
| |
Natural Gas Supply (Water Column) – in (cm) |
|
|
|
|
|
|
5-8 |
(12.7-20.3) |
| |
LP Gas Supply (Water Column) – in (cm) |
|
|
|
|
|
|
11 1/2-13 1/2 |
(29.2-34.3) |
| |
Gas Usage – 60Hz Model – BTU/hr (kW) |
|
|
|
|
|
|
145,000 |
(42.5) |
| |
Gas Usage – 50Hz Model – BTU/hr (kW) |
|
|
|
|
|
|
120,000 |
(35.2) |
| Electrical |
Gas Models |
|
Volts / Hz / Phase / Wiring |
|
|
|
|
Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability |
|
| |
-10 |
|
120 / 60 / 1 / 2 wire ground |
|
|
|
|
15 / 9.6 / #12 / Non-Reversing |
|
| |
-39 |
|
230 / 50 / 1 / 2 wire ground |
|
|
|
|
10 / 5.1 / 2.1 mm2 / Non-Reversing |
|
| |
-59 |
|
230 / 50 / 1 / 2 wire ground |
|
|
|
|
10 / 5.1 / 2.1 mm2 / Non-Reversing |
|
| |
Electric Models |
|
kW / Volts / Hz / Phase / Wiring |
|
|
|
|
Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability |
|
| |
|
|
|
|
|
|
|
|
|
| |
-79 |
|
24 / 400 / 50 / 3 / 4 wire ground |
|
|
|
|
50 / 45 / 13.3 mm2 / Non-Reversing |
|
| Installation |
Minimum Clearance Between Machines – in (cm) |
|
|
|
|
|
|
0 |
0 |
| |
Minimum Clearance Behind Machines – in (cm) |
|
|
|
|
|
|
18 |
(45.7) |
| |
Make-Up Air Required – sq ft (sq cm) |
|
|
|
|
|
|
1.25 |
(1161) |
| |
Exhaust Size – in (cm) |
|
|
|
|
|
|
8 |
(20.3) |
| |
Max. Exhaust Back Pressure (Water Column) – in (mm) |
|
|
|
|
|
|
0.3 |
(7.6) |
| |
Recommended Exhaust Length – ft (m) & 2 elbows |
|
|
|
|
|
|
14 |
(4.3) |