Cylinder Volume (per tumbler) – cu ft (L) |
|
|
|
|
|
|
|
|
15.8 |
(447.4) |
Speed |
Tumbler Speed – RPM |
|
|
|
|
|
|
|
|
45 |
— |
|
Motor Size (per tumbler) – Standard – hp (kW) |
|
|
|
|
|
|
|
|
0.75 |
(0.56) |
|
Motor Size (per tumbler) – Reversing – hp (kW) |
|
|
|
|
|
|
|
|
2 & 0.5 |
(1.5 & 0.38) |
Airflow |
60 Hz Model (per tumbler) – cfm (M3/min) |
|
|
|
|
|
|
|
|
650 |
(18.4) |
|
50 Hz Model (per tumbler) – cfm (M3/min) |
|
|
|
|
|
|
|
|
510 |
(14.4) |
Dimensions |
Cabinet Height – in (cm) |
|
|
|
|
|
|
|
|
79 1/4 |
(201.3) |
|
Cabinet Width – in (cm) |
|
|
|
|
|
|
|
|
34 1/2 |
(87.6) |
|
Cabinet Depth – in (cm) |
|
|
|
|
|
|
|
|
54 3/4 |
(139.1) |
|
Door Opening – in (cm) |
|
|
|
|
|
|
|
|
25 5/8 |
(65.1) |
|
Floor to Lower Door Bottom – in (cm) |
|
|
|
|
|
|
|
|
7 |
(17.8) |
|
Floor to Upper Door Bottom – in (cm) |
|
|
|
|
|
|
|
|
46 |
(116.8) |
|
Cylinder Diameter – in (cm) |
|
|
|
|
|
|
|
|
32 1/2 |
(82.6) |
|
Cylinder Depth – in (cm) |
|
|
|
|
|
|
|
|
33 |
(83.8) |
|
Lint Screen Area (per tumbler) – sq in (sq cm) |
|
|
|
|
|
|
|
|
544 |
(3510) |
Weight |
Net Weight – lbs (kg) |
|
|
|
|
|
|
|
|
871 |
(395.1) |
Shipping |
Shipping Weight – lbs (kg) |
|
|
|
|
|
|
|
|
922 |
(418.2) |
|
Shipping Height – in (cm) |
|
|
|
|
|
|
|
|
84 1/4 |
(214) |
|
Shipping Width – in (cm) |
|
|
|
|
|
|
|
|
36 |
(91.4) |
|
Shipping Depth – in (cm) |
|
|
|
|
|
|
|
|
61 1/2 |
(156.2) |
Gas (Gas Models Only) |
Gas Supply Connection – in (mm) |
|
|
|
|
|
|
|
|
1/2 |
(12.7) |
|
Natural Gas Supply (Water Column) – in (cm) |
|
|
|
|
|
|
|
|
5-8 |
(12.7-20.3) |
|
LP Gas Supply (Water Column) – in (cm) |
|
|
|
|
|
|
|
|
11 1/2-13 1/2 |
(29.2-34.3) |
|
Gas Usage – 60Hz Model (per tumbler) – BTU/hr (kW) |
|
|
|
|
|
|
|
|
108,000 |
(31.7) |
|
Gas Usage – 50Hz Model (per tumbler) – BTU/hr (kW) |
|
|
|
|
|
|
|
|
96,500 |
(28.3) |
Electrical |
Gas Models (per stack dryer) |
|
|
|
|
Volts / Hz / Phase / Wiring |
|
|
|
Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability |
|
|
-11 |
|
|
|
|
208-240 / 60 / 1 / 2 wire ground |
|
|
|
20 / 15 / #12 / Reversing |
|
|
-15 |
|
|
|
|
208-240 / 60 / 1 / 2 wire ground |
|
|
|
20 / 10 / #12 / Non-Reversing |
|
|
|
|
|
|
|
120 / 60 / 1 / 2 wire ground |
|
|
|
30 / 20 / #10 / Non-Reversing |
|
|
-39 |
|
|
|
|
230 / 50 / 1 / 2 wire ground |
|
|
|
— |
|
|
-49 |
|
|
|
|
240 / 50 / 1 / 2 wire ground |
|
|
|
20 / 15 / 3.5 mm2 / Reversing |
|
|
|
|
|
|
|
|
|
|
|
20 / 10 / 3.5 mm2 / Non-Reversing |
|
|
-59 |
|
|
|
|
230 / 50 / 1 / 2 wire ground |
|
|
|
20 / 10 / 3.5 mm2 / Non-Reversing |
|
|
Electric Models |
|
|
|
|
kW / Volts / Hz / Phase / Wiring |
|
|
|
Circuit Breaker Amps / Running Amps / Wire Size / Reversing Availability |
|
|
-79 |
|
|
|
|
24 / 400 / 50 / 3 / 4 wire ground |
|
|
|
— |
|
|
-82 |
|
|
|
|
15 / 400 / 50 / 3 / 4 wire ground |
|
|
|
— |
|
Installation |
Min. Clearance Between Machines – in (cm) |
|
|
|
|
|
|
|
|
0 |
0 |
|
Min. Clearance Behind Machines – in (cm) |
|
|
|
|
|
|
|
|
18 |
(45.7) |
|
Make-Up Air Required (per stack dryer) – sq ft (sq cm) |
|
|
|
|
|
|
|
|
1.5 |
(1394) |
|
Exhaust Size – in (cm) |
|
|
|
|
|
|
|
|
8 |
(20.3) |
|
Max. Exhaust Back Pressure (Water Column) – in (mm) |
|
|
|
|
|
|
|
|
0.3 |
(7.6) |
|
Recommended Exhaust Length – ft (m) & 2 elbows |
|
|
|
|
|
|
|
|
14 |
(4.3) |